Electropherogram (D5000 ScreenTape) of amplified library from low cfDNA
Posted on by
D5000 Tapestation. Performance of the D5000 and High Sensitivity D5000 ScreenTape Assays 2 Determined using D5000/High Sensitivity D5000 ladder as sample 3 Measured against 2200 TapeStation system Analytical Specifications Agilent D5000 ScreenTape Assay Agilent High Sensitivity D5000 ScreenTape Assay Sizing range 100 bp - 5,000 bp 100 bp - 5,000 bp Typical resolution 400 - 5,000 bp: 15% 400 - 5,000 bp: 15% 4 Select required sample positions in the TapeStation Controller software.
What does a good Visium Spatial Gene Expression library look like from kb.10xgenomics.com
Together with the TapeStation instruments, the DNA ScreenTape analysis offers a fast, automated, and simple solution for the reliable sample quality control (QC) of libraries in the next-generation sequencing (NGS) workflow as well as PCR and qPCR. (D1000 vs D5000) Concentration (Regular vs High Sensitivity -HS) D1000 High Sensitivity D1000 D5000 High Sensitivity D5000 Genomic DNA Volume 1 uL 2 uL 1 uL 2 uL 1 uL Size Range 35 - 1,000 bp 35 - 1,000 bp 100 - 5,000 bp.
What does a good Visium Spatial Gene Expression library look like
† The analysis of one ladder per ScreenTape device is required, for 2 - 8 ScreenTape devices a distinct higher ladder volume is prepared. It is made up of 3 elements: 2200 TapeStation system (G2964AA) or 2200 TapeStation Nucleic Acid system (G2965AA) D5000 ScreenTape (5067- 5588) with D5000 Reagents (5067- 5589) Agilent Software packages (2200 TapeStation Controller Software, and TapeStation Analysis Software) Kits The D5000 ScreenTape system is designed for analysing DNA molecules from 100. 3 Flick the D5000 ScreenTape device (5067-5588) and insert it into the ScreenTape nest of the TapeStation instrument
Direct nuclear tagmentation and RNAsequencing (DNTRseq). 3 Agilent D5000 ScreenTape System Quick Guide General Information on Working with DNA Essential Measurement Practices CAUTION Damage to the 2200 TapeStation instrument Use only the recommended consumables and reagents with the 2200 TapeStation system 3 Flick the D5000 ScreenTape device (5067-5588) and insert it into the ScreenTape nest of the TapeStation instrument
Agilent TapeStation Tayside Centre for Genomic Analysis. Together with the TapeStation instruments, the DNA ScreenTape analysis offers a fast, automated, and simple solution for the reliable sample quality control (QC) of libraries in the next-generation sequencing (NGS) workflow as well as PCR and qPCR. 3 Agilent D5000 ScreenTape Assay Quick Guide for 4200 TapeStation System Essential Measurement Practices Ladder considerations † Ladder is exclusively loaded from location A1 on the tube strip holder